Technical specifications:
|
Instalation type |
Fixed instalation |
|---|---|
|
Control panel power supply / frequency / fuse |
~ 110-230 V/50-60 Hz, max. 0.28 A with F1.6 A/250 V fuse, protection class II |
|
Power / current |
max 23 VA / 0.1 A |
|
Protection class |
II. |
|
Back-up battery |
12 V; 2.6 Ah max (lead gel) |
|
Low backup battery voltage (fault indication) |
≤11 V |
|
Maximum battery recharge time (80% capacity) |
72 h |
|
Bus supply voltage / max ripple (red – black) |
12.0 ÷ 13.8 VDC / ±100 mV |
|
Max. continuous consumption from control panel |
1000 mA |
|
– with 12 h backup (2.6 Ah battery) |
Without GSM communicator | LAN – off: 115 mA | LAN – on: 88 mA |
| With GSM communicator | LAN – off: 80 mA | LAN – on: 53 mA | |
|
Max. number of sections |
4 |
|
Max. number of peripherals |
31 peripherals + 31 remote controllers |
|
Max. number of users |
32 |
|
Max. number of PG outputs |
2 |
|
Alarm connections |
|
|
Alarm device classification |
Security level 2 / environment class II |
|
– In accordance with |
EN50131-1, EN 50131-3, EN 50131-6, EN 50131-5-3 (using the radio module), EN 50131-10, EN 50136-1, EN 50136-2 |
|
– Environment |
Indoor general |
|
– Operating temperature/humidity range |
-10 °C to +40 °C/75% non-condensing |
|
– Power supply |
Type A – primary power supply with rechargeable backup battery |
|
– Event memory capacity |
of approx. 7 million recent events including source, date and time |
|
– system response to loss of communication with periphery |
Fault or Sabotage – depending on settings and profile
|
|
– System reaction to incorrectly entered codes |
after 10 incorrectly entered codes a sabotage alarm is declared and, depending on the selected profile, all control devices are blocked for 10 minutes. |
|
– ATS classification |
Supported ATS classes: SP2 – SP5, DP2 – DP4
SPT: Type Z Type of operation: Pass-through LAN on board: SP2 – SP5 (with IP protocol) JA-194Y LITE SP3 – SP5 (JABLO IP, ANSI SIA, DC-09) LAN + JA-194Y LITE DP2 – DP4 JABLO IP, ANSI SIA, DC-09) |
|
– ATS alarm transmission protocols |
JABLO IP, SIA IP, Contact ID, |
|
– ATC security against substitution and information protection |
Jablotron protocols: proprietary AES encryption with minimum 128-bit ANSI SIA key
DC-09.2012 protocol with 128-bit AES encryption |
|
LAN communicator |
Ethernet interface CAT 5 (RJ-45) |
|
Dimensions |
268 x 225 x 83 mm |
|
Weight with/ without ACU |
1809 g/919 g |
|
Basic parameters of the JA-111R module |
868.1 MHz, <25 mW, GFSK <80 kHz |
|
Radio emission |
ETSI EN 300 220-2 (JA-111R module) |
|
EMC |
EN 50130-4, EN 55032, ETSI EN 301 489-1, ETSI EN 301 489-3 |
|
Electrical safety |
EN IEC 62368-1 |
|
Conditions of operation of the CTU radio module |
ERC REC 70-03 |
|
Certification body |
TREZOR TEST (No. 3025) |