{"id":5073,"date":"2025-03-18T04:52:32","date_gmt":"2025-03-18T04:52:32","guid":{"rendered":"https:\/\/vietbee.com\/?post_type=product&#038;p=5073"},"modified":"2025-03-18T05:06:41","modified_gmt":"2025-03-18T05:06:41","slug":"bang-dieu-khien-he-thong-canh-bao-trung-tam-ja-102kry-jablotron","status":"publish","type":"product","link":"https:\/\/vietbee.com\/en\/product\/bang-dieu-khien-he-thong-canh-bao-trung-tam-ja-102kry-jablotron\/","title":{"rendered":"JA-102KRY JABLOTRON Mercury Alarm system control panel"},"content":{"rendered":"<div>\n<p><span style=\"font-size: 130%;\"><strong><span style=\"color: #000000;\">Technical specifications:<\/span><\/strong><\/span><\/p>\n<\/div>\n<div>\n<table>\n<tbody>\n<tr>\n<th>\n<p style=\"text-align: left;\"><span style=\"font-size: 120%; color: #000000;\">Instalation type<\/span><\/p>\n<\/th>\n<td><span style=\"font-size: 120%; color: #000000;\">Fixed instalation<\/span><\/td>\n<\/tr>\n<tr>\n<th>\n<p style=\"text-align: left;\"><span style=\"font-size: 120%; color: #000000;\">Control panel power supply \/ frequency \/ fuse<\/span><\/p>\n<\/th>\n<td><span style=\"font-size: 120%; color: #000000;\">~ 110-230 V\/50-60 Hz, max. 0.28 A with F1.6 A\/250 V fuse, protection class II<\/span><\/td>\n<\/tr>\n<tr>\n<th>\n<p style=\"text-align: left;\"><span style=\"font-size: 120%; color: #000000;\">Power \/ current<\/span><\/p>\n<\/th>\n<td><span style=\"font-size: 120%; color: #000000;\">max 23 VA \/ 0.1 A<\/span><\/td>\n<\/tr>\n<tr>\n<th>\n<p style=\"text-align: left;\"><span style=\"font-size: 120%; color: #000000;\">Protection class<\/span><\/p>\n<\/th>\n<td><span style=\"font-size: 120%; color: #000000;\">II.<\/span><\/td>\n<\/tr>\n<tr>\n<th>\n<p style=\"text-align: left;\"><span style=\"font-size: 120%; color: #000000;\">Back-up battery<\/span><\/p>\n<\/th>\n<td><span style=\"font-size: 120%; color: #000000;\">12 V; 2.6 Ah max (lead gel)<\/span><\/td>\n<\/tr>\n<tr>\n<th>\n<p style=\"text-align: left;\"><span style=\"font-size: 120%; color: #000000;\">Low backup battery voltage (fault indication)<\/span><\/p>\n<\/th>\n<td><span style=\"font-size: 120%; color: #000000;\">\u226411 V<\/span><\/td>\n<\/tr>\n<tr>\n<th>\n<p style=\"text-align: left;\"><span style=\"font-size: 120%; color: #000000;\">Maximum battery recharge time (80% capacity)<\/span><\/p>\n<\/th>\n<td><span style=\"font-size: 120%; color: #000000;\">72 h<\/span><\/td>\n<\/tr>\n<tr>\n<th>\n<p style=\"text-align: left;\"><span style=\"font-size: 120%; color: #000000;\">Bus supply voltage \/ max ripple (red &#8211; black)<\/span><\/p>\n<\/th>\n<td><span style=\"font-size: 120%; color: #000000;\">12.0 \u00f7 13.8 VDC \/ \u00b1100 mV<\/span><\/td>\n<\/tr>\n<tr>\n<th>\n<p style=\"text-align: left;\"><span style=\"font-size: 120%; color: #000000;\">Max. continuous consumption from control panel<\/span><\/p>\n<\/th>\n<td><span style=\"font-size: 120%; color: #000000;\">1000 mA<\/span><\/td>\n<\/tr>\n<tr>\n<th>\n<p style=\"text-align: left;\"><span style=\"font-size: 120%; color: #000000;\">&#8211; with 12 h backup (2.6 Ah battery)<\/span><\/p>\n<\/th>\n<td><span style=\"font-size: 120%; color: #000000;\">Without GSM communicator | LAN &#8211; off: 115 mA | LAN &#8211; on: 88 mA<\/span><\/td>\n<\/tr>\n<tr>\n<th><\/th>\n<td><span style=\"font-size: 120%; color: #000000;\">With GSM communicator | LAN &#8211; off: 80 mA | LAN &#8211; on: 53 mA<\/span><\/td>\n<\/tr>\n<tr>\n<th>\n<p style=\"text-align: left;\"><span style=\"font-size: 120%; color: #000000;\">Max. number of sections<\/span><\/p>\n<\/th>\n<td><span style=\"font-size: 120%; color: #000000;\">4<\/span><\/td>\n<\/tr>\n<tr>\n<th>\n<p style=\"text-align: left;\"><span style=\"font-size: 120%; color: #000000;\">Max. number of peripherals<\/span><\/p>\n<\/th>\n<td><span style=\"font-size: 120%; color: #000000;\">31 peripherals + 31\u00a0remote controllers\u00a0<\/span><\/td>\n<\/tr>\n<tr>\n<th>\n<p style=\"text-align: left;\"><span style=\"font-size: 120%; color: #000000;\">Max. number of users<\/span><\/p>\n<\/th>\n<td><span style=\"font-size: 120%; color: #000000;\">32<\/span><\/td>\n<\/tr>\n<tr>\n<th>\n<p style=\"text-align: left;\"><span style=\"font-size: 120%; color: #000000;\">Max. number of PG outputs<\/span><\/p>\n<\/th>\n<td><span style=\"font-size: 120%; color: #000000;\">2<\/span><\/td>\n<\/tr>\n<tr>\n<th>\n<p style=\"text-align: left;\"><span style=\"font-size: 120%; color: #000000;\">Alarm connections<\/span><\/p>\n<\/th>\n<td>\n<ul>\n<li><span style=\"font-size: 120%; color: #000000;\">Jablotron bus &#8211; dedicated cable connection<\/span><\/li>\n<li><span style=\"font-size: 120%; color: #000000;\">Wireless connection (with JA-111R) &#8211; non-specific wireless connection, wireless<\/span><\/li>\n<li><span style=\"font-size: 120%; color: #000000;\">Jablotron protocol<\/span><\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<th>\n<p style=\"text-align: left;\"><span style=\"font-size: 120%; color: #000000;\">Alarm device classification<\/span><\/p>\n<\/th>\n<td><span style=\"font-size: 120%; color: #000000;\">Security level 2 \/ environment class II<\/span><\/td>\n<\/tr>\n<tr>\n<th>\n<p style=\"text-align: left;\"><span style=\"font-size: 120%; color: #000000;\">&#8211; In accordance with<\/span><\/p>\n<\/th>\n<td><span style=\"font-size: 120%; color: #000000;\">EN50131-1, EN 50131-3, EN 50131-6, EN 50131-5-3 (using the radio module), EN 50131-10, EN 50136-1, EN 50136-2<\/span><\/td>\n<\/tr>\n<tr>\n<th>\n<p style=\"text-align: left;\"><span style=\"font-size: 120%; color: #000000;\">&#8211; Environment<\/span><\/p>\n<\/th>\n<td><span style=\"font-size: 120%; color: #000000;\">Indoor general<\/span><\/td>\n<\/tr>\n<tr>\n<th>\n<p style=\"text-align: left;\"><span style=\"font-size: 120%; color: #000000;\">&#8211; Operating temperature\/humidity range<\/span><\/p>\n<\/th>\n<td><span style=\"font-size: 120%; color: #000000;\">-10 \u00b0C to +40 \u00b0C\/75% non-condensing<\/span><\/td>\n<\/tr>\n<tr>\n<th>\n<p style=\"text-align: left;\"><span style=\"font-size: 120%; color: #000000;\">&#8211; Power supply<\/span><\/p>\n<\/th>\n<td><span style=\"font-size: 120%; color: #000000;\">Type A &#8211; primary power supply with rechargeable backup battery<\/span><\/td>\n<\/tr>\n<tr>\n<th>\n<p style=\"text-align: left;\"><span style=\"font-size: 120%; color: #000000;\">&#8211; Event memory capacity<\/span><\/p>\n<\/th>\n<td><span style=\"font-size: 120%; color: #000000;\">of approx. 7 million recent events including source, date and time<\/span><\/td>\n<\/tr>\n<tr>\n<th>\n<p style=\"text-align: left;\"><span style=\"font-size: 120%; color: #000000;\">&#8211; system response to loss of communication with periphery<\/span><\/p>\n<\/th>\n<td><span style=\"font-size: 120%; color: #000000;\">Fault or Sabotage &#8211; depending on settings and profile<\/span><\/p>\n<ul>\n<li><span style=\"font-size: 120%; color: #000000;\">bus up to 10 s<\/span><\/li>\n<li><span style=\"font-size: 120%; color: #000000;\">wireless communication up to 2 h (since last communication)<\/span><\/li>\n<li><span style=\"font-size: 120%; color: #000000;\">wireless communication within 20 min prevents securing the section<\/span><\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<th>\n<p style=\"text-align: left;\"><span style=\"font-size: 120%; color: #000000;\">&#8211; System reaction to incorrectly entered codes<\/span><\/p>\n<\/th>\n<td><span style=\"font-size: 120%; color: #000000;\">after 10 incorrectly entered codes a sabotage alarm is declared and, depending on the selected profile, all control devices are blocked for 10 minutes.<\/span><\/td>\n<\/tr>\n<tr>\n<th>\n<p style=\"text-align: left;\"><span style=\"font-size: 120%; color: #000000;\">&#8211; ATS classification<\/span><\/p>\n<\/th>\n<td><span style=\"font-size: 120%; color: #000000;\">Supported ATS classes: SP2 &#8211; SP5, DP2 &#8211; DP4<\/span><\/p>\n<p><span style=\"font-size: 120%; color: #000000;\">SPT: Type Z<\/span><\/p>\n<p><span style=\"font-size: 120%; color: #000000;\">Type of operation: Pass-through<\/span><\/p>\n<p><span style=\"font-size: 120%; color: #000000;\">LAN on board: SP2 &#8211; SP5 (with IP protocol)<\/span><\/p>\n<p><span style=\"font-size: 120%; color: #000000;\">JA-194Y LITE SP3 &#8211; SP5 (JABLO IP, ANSI SIA, DC-09)<\/span><\/p>\n<p><span style=\"font-size: 120%; color: #000000;\">LAN + JA-194Y LITE DP2 &#8211; DP4 JABLO IP, ANSI SIA, DC-09)<\/span><\/td>\n<\/tr>\n<tr>\n<th>\n<p style=\"text-align: left;\"><span style=\"font-size: 120%; color: #000000;\">&#8211; ATS alarm transmission protocols<\/span><\/p>\n<\/th>\n<td><span style=\"font-size: 120%; color: #000000;\">JABLO IP, SIA IP, Contact ID,<\/span><\/td>\n<\/tr>\n<tr>\n<th>\n<p style=\"text-align: left;\"><span style=\"font-size: 120%; color: #000000;\">&#8211; ATC security against substitution and information protection<\/span><\/p>\n<\/th>\n<td><span style=\"font-size: 120%; color: #000000;\">Jablotron protocols: proprietary AES encryption with minimum 128-bit ANSI SIA key<\/span><\/p>\n<p><span style=\"font-size: 120%; color: #000000;\">DC-09.2012 protocol with 128-bit AES encryption<\/span><\/td>\n<\/tr>\n<tr>\n<th>\n<p style=\"text-align: left;\"><span style=\"font-size: 120%; color: #000000;\">LAN communicator<\/span><\/p>\n<\/th>\n<td><span style=\"font-size: 120%; color: #000000;\">Ethernet interface CAT 5 (RJ-45)<\/span><\/td>\n<\/tr>\n<tr>\n<th>\n<p style=\"text-align: left;\"><span style=\"font-size: 120%; color: #000000;\">Dimensions<\/span><\/p>\n<\/th>\n<td><span style=\"font-size: 120%; color: #000000;\">268 x 225 x 83 mm<\/span><\/td>\n<\/tr>\n<tr>\n<th>\n<p style=\"text-align: left;\"><span style=\"font-size: 120%; color: #000000;\">Weight with\/ without ACU<\/span><\/p>\n<\/th>\n<td><span style=\"font-size: 120%; color: #000000;\">1809 g\/919 g<\/span><\/td>\n<\/tr>\n<tr>\n<th>\n<p style=\"text-align: left;\"><span style=\"font-size: 120%; color: #000000;\">Basic parameters of the JA-111R module<\/span><\/p>\n<\/th>\n<td><span style=\"font-size: 120%; color: #000000;\">868.1 MHz, &lt;25 mW, GFSK &lt;80 kHz<\/span><\/td>\n<\/tr>\n<tr>\n<th>\n<p style=\"text-align: left;\"><span style=\"font-size: 120%; color: #000000;\">Radio emission<\/span><\/p>\n<\/th>\n<td><span style=\"font-size: 120%; color: #000000;\">ETSI EN 300 220-2 (JA-111R module)<\/span><\/td>\n<\/tr>\n<tr>\n<th>\n<p style=\"text-align: left;\"><span style=\"font-size: 120%; color: #000000;\">EMC<\/span><\/p>\n<\/th>\n<td><span style=\"font-size: 120%; color: #000000;\">EN 50130-4, EN 55032, ETSI EN 301 489-1, ETSI EN 301 489-3<\/span><\/td>\n<\/tr>\n<tr>\n<th>\n<p style=\"text-align: left;\"><span style=\"font-size: 120%; color: #000000;\">Electrical safety<\/span><\/p>\n<\/th>\n<td><span style=\"font-size: 120%; color: #000000;\">EN IEC 62368-1<\/span><\/td>\n<\/tr>\n<tr>\n<th>\n<p style=\"text-align: left;\"><span style=\"font-size: 120%; color: #000000;\">Conditions of operation of the CTU radio module<\/span><\/p>\n<\/th>\n<td><span style=\"font-size: 120%; color: #000000;\">ERC REC 70-03<\/span><\/td>\n<\/tr>\n<tr>\n<th>\n<p style=\"text-align: left;\"><span style=\"font-size: 120%; color: #000000;\">Certification body<\/span><\/p>\n<\/th>\n<td><span style=\"font-size: 120%; color: #000000;\">TREZOR TEST (No. 3025)<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"text-align: left;\">\n<\/div>","protected":false},"excerpt":{"rendered":"<p><span style=\"font-size: 120%;\"><strong><span style=\"color: #000000;\">The JA-102K control panel offers:<\/span><\/strong><\/span><\/p>\n<ul>\n<li><span style=\"color: #000000; font-size: 120%;\">up to 31 wireless or bus peripherals<\/span><\/li>\n<li><span style=\"color: #000000; font-size: 120%;\">up to 32 users<\/span><\/li>\n<li><span style=\"color: #000000; font-size: 120%;\">up to 4 sections<\/span><\/li>\n<li><span style=\"color: #000000; font-size: 120%;\">up to 2 programmable PG outputs<\/span><\/li>\n<\/ul>\n<p><span style=\"font-size: 120%;\"><strong><span style=\"color: #000000;\">The control panel has:<\/span><\/strong><\/span><\/p>\n<ul>\n<li><span style=\"color: #000000; font-size: 120%;\">1 terminal block for bus connection<\/span><\/li>\n<li><span style=\"color: #000000; font-size: 120%;\">1 connector for built-in radio module (JA-111R)<\/span><\/li>\n<li><span style=\"color: #000000; font-size: 120%;\">1 connector for GSM\/GPRS communicator (JA-194Y-LITE)<\/span><\/li>\n<\/ul>\n","protected":false},"featured_media":5074,"template":"","meta":[],"product_brand":[],"product_cat":[2800],"product_tag":[2807,2804,2805,2806],"pa_bo-nho-trong":[],"pa_bo-vi-xu-ly":[],"pa_do-dai":[],"pa_do-phan-giai":[],"pa_hang-san-xuat":[],"pa_kich-thuoc-man-hinh":[],"pa_micro-thu-am":[],"pa_nha-thong-minh-rang-dong":[],"pa_o-cung":[],"pa_ong-kinh":[],"pa_poe":[],"pa_ports":[],"pa_tam-quan-sat":[],"pa_theo-chuan":[],"class_list":{"0":"post-5073","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-giai-phap-an-ninh","7":"product_tag-bang-dieu-khien-trung-tam","8":"product_tag-giai-phap-an-ninh","9":"product_tag-ja-102kry","10":"product_tag-jablotron","12":"first","13":"instock","14":"shipping-taxable","15":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/vietbee.com\/en\/wp-json\/wp\/v2\/product\/5073","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/vietbee.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/vietbee.com\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/vietbee.com\/en\/wp-json\/wp\/v2\/media\/5074"}],"wp:attachment":[{"href":"https:\/\/vietbee.com\/en\/wp-json\/wp\/v2\/media?parent=5073"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/vietbee.com\/en\/wp-json\/wp\/v2\/product_brand?post=5073"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/vietbee.com\/en\/wp-json\/wp\/v2\/product_cat?post=5073"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/vietbee.com\/en\/wp-json\/wp\/v2\/product_tag?post=5073"},{"taxonomy":"pa_bo-nho-trong","embeddable":true,"href":"https:\/\/vietbee.com\/en\/wp-json\/wp\/v2\/pa_bo-nho-trong?post=5073"},{"taxonomy":"pa_bo-vi-xu-ly","embeddable":true,"href":"https:\/\/vietbee.com\/en\/wp-json\/wp\/v2\/pa_bo-vi-xu-ly?post=5073"},{"taxonomy":"pa_do-dai","embeddable":true,"href":"https:\/\/vietbee.com\/en\/wp-json\/wp\/v2\/pa_do-dai?post=5073"},{"taxonomy":"pa_do-phan-giai","embeddable":true,"href":"https:\/\/vietbee.com\/en\/wp-json\/wp\/v2\/pa_do-phan-giai?post=5073"},{"taxonomy":"pa_hang-san-xuat","embeddable":true,"href":"https:\/\/vietbee.com\/en\/wp-json\/wp\/v2\/pa_hang-san-xuat?post=5073"},{"taxonomy":"pa_kich-thuoc-man-hinh","embeddable":true,"href":"https:\/\/vietbee.com\/en\/wp-json\/wp\/v2\/pa_kich-thuoc-man-hinh?post=5073"},{"taxonomy":"pa_micro-thu-am","embeddable":true,"href":"https:\/\/vietbee.com\/en\/wp-json\/wp\/v2\/pa_micro-thu-am?post=5073"},{"taxonomy":"pa_nha-thong-minh-rang-dong","embeddable":true,"href":"https:\/\/vietbee.com\/en\/wp-json\/wp\/v2\/pa_nha-thong-minh-rang-dong?post=5073"},{"taxonomy":"pa_o-cung","embeddable":true,"href":"https:\/\/vietbee.com\/en\/wp-json\/wp\/v2\/pa_o-cung?post=5073"},{"taxonomy":"pa_ong-kinh","embeddable":true,"href":"https:\/\/vietbee.com\/en\/wp-json\/wp\/v2\/pa_ong-kinh?post=5073"},{"taxonomy":"pa_poe","embeddable":true,"href":"https:\/\/vietbee.com\/en\/wp-json\/wp\/v2\/pa_poe?post=5073"},{"taxonomy":"pa_ports","embeddable":true,"href":"https:\/\/vietbee.com\/en\/wp-json\/wp\/v2\/pa_ports?post=5073"},{"taxonomy":"pa_tam-quan-sat","embeddable":true,"href":"https:\/\/vietbee.com\/en\/wp-json\/wp\/v2\/pa_tam-quan-sat?post=5073"},{"taxonomy":"pa_theo-chuan","embeddable":true,"href":"https:\/\/vietbee.com\/en\/wp-json\/wp\/v2\/pa_theo-chuan?post=5073"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}