Description:
The JA-107K is an advanced version of the JABLOTRON 100+ security system. It is designed for large living spaces, offices and businesses.
Technical specifications:
Control panel power supply | ~ 110 – 230 V/50 – 60 Hz, max. 0.85 A with fuse F1.6 A/250 V, Protection class II | ||
---|---|---|---|
Back-up battery | 12 V; 7 to 18 Ah (lead gel) | ||
Maximum battery charging time | 48 h | ||
BUS voltage (red – black) | 12.0 to 13.8 V | ||
Maximum continuous current consumption from the control panel | 2000 mA permanent 3000 mA for 60 minutes (max. 2000 mA for one BUS) |
||
Max. continuous current consumption for back-up 12 hours | Without GSM communicator | LAN – OFF: 1135 mA LAN – ON: 1107 mA |
|
With GSM communicator | LAN – OFF: 1100 mA LAN – ON: 1072 mA |
||
Max. continuous current consumption for back-up 24 hours | Without GSM communicator | LAN – OFF: 535 mA LAN – ON: 499 mA |
|
With GSM communicator | LAN – OFF: 530 mA
LAN – ON: 494 mA |
||
Maximum number of devices | 230 | ||
LAN communicator | Ethernet interface, 10/100BASE | ||
Dimensions | 357 x 297 x 105 mm | ||
Weight with/without AKU | 7027 g/1809 g | ||
Reaction to invalid code entry | Alarm after 10 wrong code entries | ||
Event memory | Approx. 7 million latest events, including date and time | ||
Power supply unit | Type A according to EN 50131-6 T 031 note: In case of a main power failure is the system backed up for 24 hours and at the same time is a failure report sent to the ARC. |
||
GSM communicator | 850 / 900 / 1800 / 1900 MHz | ||
Classification | Security grade 2 according to EN 50131-1 | ||
Operational environment | Environmental class II (indoor general) according to EN 50131-1 | ||
Operational temperature range | -10 °C to +40 °C | ||
Average operational humidity | 75 % RH, non-condensing | ||
Complies with | EN 50131-1 ed. 2+A1+A2, EN 50131-3, EN 50131-5-3+A1, EN 50131-6 ed. 2+A1, EN 50131-10, EN 50136-1, EN 50136-2, EN 50581 |
||
Radio operating frequency (with the JA 11xR module) | 868.1 MHz | ||
Radio emissions | ETSI EN 300 220-1,-2 (module R), ETSI EN 301 419-1, ETSI EN 301 511 (GSM) | ||
EMC | EN 50130-4 ed. 2+A1, EN 55032 ed. 2, ETSI EN 301 489-7 | ||
Safety conformity | EN 62368-1+A11 | ||
Caller identification (CLIP) | ETSI EN 300 089 | ||
Operational conditions | ERC REC 70-03 | ||
Certification body | Trezor Test s.r.o. (no. 3025) |