JA-102KRY JABLOTRON Mercury Alarm system control panel

The JA-102K control panel offers:

  • up to 31 wireless or bus peripherals
  • up to 32 users
  • up to 4 sections
  • up to 2 programmable PG outputs

The control panel has:

  • 1 terminal block for bus connection
  • 1 connector for built-in radio module (JA-111R)
  • 1 connector for GSM/GPRS communicator (JA-194Y-LITE)

Technical specifications:

Instalation type

Fixed instalation

Control panel power supply / frequency / fuse

~ 110-230 V/50-60 Hz, max. 0.28 A with F1.6 A/250 V fuse, protection class II

Power / current

max 23 VA / 0.1 A

Protection class

II.

Back-up battery

12 V; 2.6 Ah max (lead gel)

Low backup battery voltage (fault indication)

≤11 V

Maximum battery recharge time (80% capacity)

72 h

Bus supply voltage / max ripple (red – black)

12.0 ÷ 13.8 VDC / ±100 mV

Max. continuous consumption from control panel

1000 mA

– with 12 h backup (2.6 Ah battery)

Without GSM communicator | LAN – off: 115 mA | LAN – on: 88 mA
With GSM communicator | LAN – off: 80 mA | LAN – on: 53 mA

Max. number of sections

4

Max. number of peripherals

31 peripherals + 31 remote controllers 

Max. number of users

32

Max. number of PG outputs

2

Alarm connections

  • Jablotron bus – dedicated cable connection
  • Wireless connection (with JA-111R) – non-specific wireless connection, wireless
  • Jablotron protocol

Alarm device classification

Security level 2 / environment class II

– In accordance with

EN50131-1, EN 50131-3, EN 50131-6, EN 50131-5-3 (using the radio module), EN 50131-10, EN 50136-1, EN 50136-2

– Environment

Indoor general

– Operating temperature/humidity range

-10 °C to +40 °C/75% non-condensing

– Power supply

Type A – primary power supply with rechargeable backup battery

– Event memory capacity

of approx. 7 million recent events including source, date and time

– system response to loss of communication with periphery

Fault or Sabotage – depending on settings and profile

  • bus up to 10 s
  • wireless communication up to 2 h (since last communication)
  • wireless communication within 20 min prevents securing the section

– System reaction to incorrectly entered codes

after 10 incorrectly entered codes a sabotage alarm is declared and, depending on the selected profile, all control devices are blocked for 10 minutes.

– ATS classification

Supported ATS classes: SP2 – SP5, DP2 – DP4

SPT: Type Z

Type of operation: Pass-through

LAN on board: SP2 – SP5 (with IP protocol)

JA-194Y LITE SP3 – SP5 (JABLO IP, ANSI SIA, DC-09)

LAN + JA-194Y LITE DP2 – DP4 JABLO IP, ANSI SIA, DC-09)

– ATS alarm transmission protocols

JABLO IP, SIA IP, Contact ID,

– ATC security against substitution and information protection

Jablotron protocols: proprietary AES encryption with minimum 128-bit ANSI SIA key

DC-09.2012 protocol with 128-bit AES encryption

LAN communicator

Ethernet interface CAT 5 (RJ-45)

Dimensions

268 x 225 x 83 mm

Weight with/ without ACU

1809 g/919 g

Basic parameters of the JA-111R module

868.1 MHz, <25 mW, GFSK <80 kHz

Radio emission

ETSI EN 300 220-2 (JA-111R module)

EMC

EN 50130-4, EN 55032, ETSI EN 301 489-1, ETSI EN 301 489-3

Electrical safety

EN IEC 62368-1

Conditions of operation of the CTU radio module

ERC REC 70-03

Certification body

TREZOR TEST (No. 3025)